Guide to evaluation of strength test results of concrete aci 214r11 3 s sample standard deviation, an estimate of the population standard devi ation, also termed s overall s statistical average standard deviation, or pooled standard deviation s 1 sample withinbatch standard deviation, also termed s withinbatch s. Changes from aci 31811 to aci 31814 are discussed in this paper. Aci 301specifications for structural concrete for buildings. Specifications for structural concrete, aci 30110, with. It includes index plus six 6 volumes that encompass all aci code documents. Specifications for structural concrete, aci 30105, with. All books are in clear copy here, and all files are secure so dont worry about it. Information derived from such procedures is also valuable in defining design criteria and specifications. Aci 214r11 guide to evaluation of strength test results. This site is like a library, you could find million book here by using search box in the. Aci 301 is a re f e r ence standard which the engineer or architect may make applicable to any building project by citing it in the project specifications. Aci 117, except that fabrication tolerance for bar sizes. Aci 56216 into state and municipal building codes, and into the regulatory standards of other groups.
Guide to evaluation of strength test results of concrete. Oct 21, 2012 this is a full set of american concrete institute aci manual of concrete practice mcp 2010 edition. It focuses on basic castinplace work and does not deal with specialty concre t e s. Building code requirements for masonry structures ciii code and commentary, ciii building code requirements for masonry structures tms 402xxaci 530xxasce 5xx synopsis this code covers the design and construction of masonry structures. Aci 318052 requires that the target average strength should be the maximum of the following two equations. It is written in such form that it may be adopted by reference in a legally adopted building code.
Acis manual of concrete practice mcp is the most comprehensive concrete reference set available. Aci 214r 02 provides a means to judge the quality of testing. Aci214 recommended practice for evaluation of strength. Aci 214r 02 evaluation of strength test results of concrete.
Read online concrete mix construventas book pdf free download link book now. Oz a mathematical analysis, using statistical techniques, for prediction of compressive strength of concrete was performed for the concrete strength data obtained from experimental work conducted. En 2061 and aci 214r 02 and compared to the strength. Aci31808 code requirements for design of concrete floor systems1 this technical note details the requirements of aci318 08 for design of concrete floor systems, with emphasis on posttensioning and their implementation in the adapt builder platform programs.
The institute shall not be liable for any loss or damage. Aci manual of concrete practice civil engineering community. Building code requirements for structural concrete and commentary. Oct 20, 2012 aci s manual of concrete practice mcp is the most comprehensive concrete reference set available. Introduction this guide provides an introduction to the evaluation of concrete strength test results. Scribd is the worlds largest social reading and publishing site. Some other re f e re n c e specifications available from aci include the follow i n g. Reference to this document shall not be made in con aci 214r 02 supersedes aci 21477 reapproved 1997 and became effective tract documents. Aci 214r11 guide to evaluation of strength test results of concrete author. Specifications for structural concrete, aci 30105, with selected aci references. Aci 117, except that fabrication tolerance for bar sizes nos. Aci 301 is a specification for stru c t u r al concrete in b u i l d i n g s. Content description this code provides requirements for test load magnitudes, test protocols, and acceptance criteria for conducting a load test as a means of evaluating the safety and serviceability of concrete structural members and systems for existing buildings as provided for by aci 562. Barry butler bryant mather members of the committee voting on the 1991 revisions.
Aci 214r 2011 evaluation of strength test results of. Aci 214r11 guide to evaluation of strength test results of. Astm c 33, provide aggregate free from any substance which may be. Standard specifications for structural concrete aci 30110. Since the characteristic compressive strength of concrete selected for the present work was 50 mpa, corresponding values were referred from aci 214r 02.
It categorizes as excellent, very good, good, fair and poor based on coefficient of variation values as less than 2%, 23%, 34%, 45% and more than 5% respectively. Statistical procedures provide tools of considerable value when evaluating the results of strength tests. Evaluation of strength test results of concrete aci 214r 02. Evaluation of strength test results of concrete aci 214r02. Generally, cores are obtained either to assess whether suspect concrete in a new structure complies with. Covers an introduction to the evaluation of concrete strength test results.
Guide to evaluation of strength test results of concrete aci 214r11 3 s sample standard deviation. Prediction of the curing time to achieve maturity of the. It contains all of the widely used aci concrete and masonry code requirements, specifications, guides and reports. Aci mcp 2010 manual of concrete practice 2010 this is a full set of american concrete institute aci manual of concrete practice mcp. Founded in 1904 and headquartered in farmington hills, michigan, usa, the american concrete institute is a leading authority and resource worldwide for the development, dissemination, and adoption of its consensusbased standards, technical resources, educational programs, and proven expertise for individuals and organizations involved in concrete design. Pdf using conformity control of concrete compressive.
Procedures described are applicable to the compressive strength test results required by aci 301, aci 318, and similar specifications and codes. Aci manual of concrete practice mcp is the most comprehensive concrete reference set available. Aci 31814 contains a number of significant technical changes, with some of the most important in chapter 18, earthquake resistant structures. Significant changes from the 2011 to the 2014 edition of aci 318 satyendra k. A procedure is presented for proportioning concrete that has slumps in the range of zero to 25 mm 1 in. Pdf aci 31805 building code requirements for structural. Aci mcp 2010 manual of concrete practice 2010 civil. The american concrete institute disclaims any and all responsibility for the stated principles. Guide for obtaining cores and interpreting compressive strength results aci 214. Guide to evaluation of strength test results of concrete aci 214r 11 3 s sample standard deviation. Specifications for structural concrete, aci 30110, with selected aci and astm references. At the very least, we would hope to have 15 to 29 consecutive tests and could still calculate our standard deviation and apply a multiplier from table 5. Usa, the american concrete institute is a leading authority and resource worldwide for the development and distribution of consensusbased standards, technical resources.
Read pdf aci 214r11 guide to evaluation of strength. Aci 214r 11 guide to evaluation of strength test results of concrete author. Itg304 report on bridge decks free of steelreinforcement part 6. Concrete mix construventas pdf book manual free download. He supplements it as needed by designating or specifying indi. Compressive strength, porosity and sorptivity of ultra. Concrete quality control nrmca expanding the concrete. Significant changes from the 2011 to the 2014 edition of aci 318. Aci214 recommended practice for evaluation of strength test resultsof concrete aci214 errata superseded see the following.
An essential reference document containing american concrete association aci documents. As a published standard, aci 56216 establishes a standard of care for design professionals involved with repair of existing concrete structures consis tent with iebc requirements. Aci214r show complete document history how to order. Ac sp15 feld reference manual standard specfcatons for structural concrete ac 30110 wselected ac referencesto purchase contact hs at 18008547179 usacanada or 3033977956 worldwde. Compressive strength, porosity and sorptivity of ultra fine. Aci committee reports, guides, standard practices, and commentaries are intended for guidance in planning, designing, executing, and inspecting construction.
Additionally, aci 214r 02 reported that usually 28 days are required to yield adequate curing of the portland cement based concrete. It categorizes as excellent, very good, good, fair and poor based on coefficient of variation values as less than 2%, 23%, 34%, 45% and more than 5%. Significant changes from the 2011 to the 2014 edition of. Aci 214r 11 supersedes 214r 02 and was adopted and published april 2011.
347 819 176 282 508 1059 1304 1422 1280 837 1389 227 971 388 711 1064 1323 750 1325 1084 190 1373 326 298 771 1377 120 258 214 271 49 1159 1053 1152 700 1261 1431 1093 724